OUR
ALLIES
COURSES
THEORETICAL AND PRACTICAL
We offer theoretical and practical courses for engineers and electrical technicians on electrical concepts and testing.
SERVICE OF
LABORATORY
We have a complete laboratory for calibration and repair of test instruments with which we provide after-sales support.
PRODUCTS/Omicron
OMICRON is an international company serving the electric power industry with innovative test and diagnostic solutions for primary and secondary injection systems.
BOW 400
Universal Test Set for Recloser Controls
ARCO 400 is a smart and rugged solution for testing recloser control. It provides the fastest way to perform manual tripping and recloser checking. Utilizing OMICRON intelligent connection technology, ARCO 400 is able to detect recloser specific test adapters.
The device simulates the recloser and allows three-phase testing of the controller in both laboratory and field environments. ARCO 400 is equipped with 3 accurate 12.5A current amplifiers, 6-phase voltage amplifiers (8 V or 150 V range), six binary inputs, and nine binary outputs.
PRIMARY INJECTION TESTING
Electrical diagnostics CPC-100
The CPC 100 can be used to perform electrical tests on transformers, current transformers, voltage transformers, grounding systems, power lines and cables and circuit breakers.
The patented test system replaces several individual test devices and offers new and innovative test methods.
The CPC 100 is the basis for various accessories. These enable new applications, e.g. Tan Delta measurements, as well as line and ground impedance measurements.
FRANEO 800
Isolation monitors for main current circuits in IT systems, (Motors, Pumps) - without directly connected rectifiers.
FRANEO 800 replaces the existing FRAnalyzer Measurement System, provides hardware enhancements and new software functionality:
- Largest dynamic range in the SFRA test industry (>145dB)
- High accuracy measurements (±0.5 dB guaranteed)
- Grounding check for connection verification and to ensure greater reproducibility in tests.
- Wide frequency range (1Hz to 30Mhz).
- Freely adjustable output voltage (0.1Vpp to 10Vpp @ 50 Ohms).
- Improved accessories (new small Li-Ion battery for long operating time).
- Integrated with the Primary Test Manager (PTM) software tool for better analysis, comparison and reporting of tests.
- Import tool from the old FRAnalyzer database.
- Intelligent frequency sweep with selectable and/or adjustable profiles
- Conforms to applicable standards (IEC 60076-18 and IEEE C57.149-2012).
Dirana
Allows the detection of moisture in the oil-impregnated paper of transformers by analyzing the dielectric response.
Such a response generates useful information about the condition of the high voltage insulation. However, it is important to subject the insulation to a wide frequency band, as the typical measurement at the mains frequency limits the results.
The equipment measures the dissipation factor and capacitance of rotating machine insulation systems.
It is used to calculate the moisture content of insulation in the following applications:
- Power transformers.
- Cables insulated with paper mass.
- Terminals.
- Instrument transformers (CT/PT)
Delta Tangent
CPTD1
Omicron's transformer diagnostic system is a unique test set that facilitates automatic testing of important transformer parameters in a single portable system. The test system consists of the multifunctional CPC 100 primary test system and the CP TD1 Tangente Delta unit. The patented CPC 100 is the main control unit for the test system and the CP TD1 unit is used to test the insulation condition.
These units together constitute the system that is considered the ideal tool for complete testing of the following parameters of a power transformer:
- Winding resistance
- Transformer ratio and excitation current
- On-load tap changer status
- Leakage reactance
- Insulation condition (capacitance, delta tangent, power factor)
FRAnalyzer
Frequency response analyzer
It was developed to check the integrity of power transformers after transformer transport or the occurrence of high currents. The FRAnalyzer follows the principle of Sweep Frequency Response Analysis (SFRA) and measures the electrical transfer functions over a wide frequency range.
It detects winding defects and magnetic core faults - thus helping to increase reliability, reduce maintenance costs and avoid costly transformer failures.
Main features
- Reproducible results thanks to innovative connection technology
- Extremely small and compact device (< 1.8 kg)
- Wide dynamic measurement range (> 120 dB)
- Short measurement time (about 30 seconds per measurement)
Areas of application
The FRAnalyzer is used for transformer testing, after:
- A short circuit
- Transportation
- Occurrence of high transient fault currents
- A significant change in the recorded values (e.g. combustible gases) or a safety shutdown
The following tests can also be performed:
- Measurement of the usual operating conditions of the transformers
Verification of anomalous events detected during normal tests
CT Analyzer
A revolution in current transformer testing
- Highest measurement accuracy: 0.02 % / 1 min. when calibrating in the field.
- Very small and light (< 8 kg), easy to transport for field trials
- Automatic evaluation according to IEC and IEEE standards
- Reduces commissioning times (automatic test duration < 1 min.)
- Outstanding workplace safety - Tests carried out at 120 V max.
- Integration into test routines via the Remote Control Interface
More Information
VOTANO 100
Accurate and mobile testing and calibration of voltage transformers
- Very high accuracy allows field calibration of TT up to 0.1 accuracy class.
- Excellent mobility due to small size and low weight (< 15 kg)
- Automatic evaluation of the result according to IEEE and IEC standards directly after testing
- Short test duration compared to conventional methods (< 20 min)
More Information
SECONDARY INJECTION TESTS
Relay test equipment
Relay Test Set CMC 356
The CMC 356 is the universal solution for testing all generations and types of protection relays. Its six powerful current sources (three-phase mode: up to 64 A / 860 VA per channel) with a large dynamic range make the unit capable of testing even high-load electromechanical relays with very high power demands.
The CMC 356 is the ideal choice for applications requiring the highest versatility, amplitude and power. Commissioning engineers especially appreciate its ability to perform wiring and plausibility checks of current transformers by primary injection of high currents from the test set.
Main features
- Very powerful current sources for testing of even high load electromechanical relays
- High current amplitudes for 5 A relay test
- High accuracy and versatility for testing of static and numerical relays of all types
- Integrated network for IEC 61850 IED device testing
- 10-channel analog measurement and transient recording functionality (option)
- CMC 356 -
Software package IEC 61850
Omicron has incorporated the most common communication protocol test tools into a single package:
- Goose Configuration Module: allows testing of protective devices with IEC 61850 GOOSE messages. It is used to configure the assignments and to configure the test set for communication with the substation network.
- Sampled Values Configuration Module: Allows the CMC test set to be configured for the generation of IEC 61850 Sampled Values. Depending on the test set model, up to three Sampled Values streams can be generated simultaneously.
- IEDScout: is a universal IEC 61850 server client (such as substation IEDs) and GOOSE message editor/subscriber. It provides many useful functions that are needed in the substation or laboratory.
SWITCH TESTING
CIBANO 500
3-in-1 test system for medium and high voltage power circuit breakers
The CIBANO 500 circuit breaker test system combines a micro-ohmmeter, a synchronism analyzer and a coil and motor power supply in a single instrument. This makes it possible to perform all important circuit breaker tests even when the substation battery is not available.
With the 3-in-1 system you can test all types of circuit breakers (medium and high voltage circuit breakers).
Main features
- 3-in-1 system: micro-ohmmeter, synchro-analyzer and AC/DC power supply
- A single system for medium- and high-voltage circuit breakers with live or dead tank design
- Little wiring work
- One clear report for all tests
- Lightweight testing system (20 kg)
PRODUCTS / Omicron
RELAY AND PROTECTION TEST EQUIPMENT
Relay test and protection test equipment for Omicron ensure the operation and reliability of complex electrical systems, allowing accurate testing of relays, switches and safety devices. They are advanced solutions for current and voltage injection, ideal for verifying the protection and quality of electrical installations.
Primary injection tests
Secondary injection tests
EQUIPMENT FOR ANALYSIS AND MONITORING
Explore Omicron's portfolio of analysis and monitoring equipment designed to provide accurate and reliable measurements in electrical systems. Ensure the performance and safety of your facilities with advanced, easy-to-use technology.
Primary injection tests
Secondary injection tests
TEST AND MANAGEMENT SOFTWARE
Programs designed to optimize the verification, analysis and maintenance of electrical systems. With advanced solutions that automate tests, manage results and ensure the reliability of installations, providing efficiency and total control.
OTHER EQUIPMENT AND TOOLS
More specialized solutions for monitoring, diagnostics and maintenance of electrical systems.
CONTACT US
Contact our team for more information about our products. Omicron.
Alejandro Cataño
Universidad del Valle
OMICRON Lines Director
(PUC)
(+57) 6014864030
Ext: 1140
DIEGO LAVAO
National University
OMICRON Lines Director
(Partial downloads)
(+57) 6014864030
Ext: 1125
Jimmy Ibañez
University of the North
OMICRON Lines Director
(CT ANALYZER - VOTANO)
(+57) 6014864030
Ext: 1126
Carlos Centeno
University of Oriente
OMICRON Lines Director
(COMPANION)
(+57) 6014864030
Ext: 1134
Jelsson Ramos
--
OMICRON Line Manager (CPC 100 - TESTRANO 600)
(+57) 6014864030
Ext: